Skip to the reports
Aquifer to TapSan Antonio house water, filed in short reports
Beats

Your pipesP-08

Flushing sediment from a water heater

Filed Nov. 11, 2026 · checked against 4 sources · Aquifer to Tap

Flushing a water heater is advice from two agencies on two schedules: SAWS says 2-3 times a year to clear hard-water sediment, while DOE says drain a quart every 3 months.

2-3times a year SAWS suggests flushing a water heaterSource: SAWS

A garden hose on a water heater's drain valve, letting cloudy water run into a floor drain
Green hose on a water heater drain valve emptying cloudy water into a garage floor drain. AI-generated picture.

In SAWS's troubleshooting table, pale sediment in the water traces back to hardness: calcium carbonate precipitates when water is heated or frozen. The table recommends flushing the heater 2-3 times a year to remove the loose material. DOE's 2022 Energy Saver Guide puts it at one quart drawn off every 3 months, done the way the manufacturer directs. Both defer to the maker, and this report does not rank one over the other.

Which schedule applies?

The heater's own manual decides. SAWS water typically measures 15 to 20 grains per gallon, according to its FAQ, so sediment is a real feature of San Antonio tanks. The maker's video on this page, from Rheem, suggests a flush every six months and more often with hard water; that is one maker's interval for its own heaters.

Three published flushing intervals (checked Nov. 11, 2026)
SourceIntervalMethod
SAWS2-3 times a yearFlush to remove loose calcium carbonate
U.S. DOEEvery 3 monthsDrain about a quart; follow maker's directions
Rheem (maker's video)Every 6 months, more with hard waterPartial flush through the drain valve

Lower tank temperature helps too. DOE says a 120°F setting slows mineral buildup and corrosion; see the 120-degree setting. Background on the scale itself is in white flakes and scale.

What a partial flush involves

The Rheem video shows the general order: power off first, a hose on the drain valve, the cold supply closed, a hot tap opened, a few gallons drained, then the tank refilled before power returns. Hot water from the drain can scald, and the manual for the specific heater governs every step.

The power rule is the same on every electric heater. The breaker goes off before draining starts and stays off for the entire flush, including any time an access panel is open. Power is restored only once the tank has refilled completely, with a hot tap running a steady stream.

On a gas heater, set the gas control as the maker's manual describes for draining, and no further. Burners, gas valves and venting belong to a licensed plumber, as the TSBPE license types describe.

What else to watch around the tank

SAWS lists standing water near the water heater as a sign of a hidden leak; see meter checks for leaks. It also says the annual backflow test on a sprinkler system does not cover thermal expansion equipment or the heater's pressure relief valve, which the owner remains responsible for maintaining, according to its backflow testing page. A leaking supply line or fill mechanism on a water heater is one of the leak types SAWS considers for a leak adjustment.

Watch How to Flush a Tank Water Heater — from the Rheem Water Heating channel, 3:33. Rheem shows a partial flush: power off at the breaker (on gas, the gas control set as the manual directs), a hose on the drain valve, cold inlet closed, a hot tap open, a few gallons drained through a stocking to catch sediment, then refill before the power goes back on.

Key facts

  • SAWS interval for hard water: two to three flushes yearly.
  • DOE interval: one quart drained each quarter, as the manual directs.
  • SAWS hardness: typically 15-20 grains per gallon.
  • Electric heater: breaker off through the whole drain and refill.
  • Gas heater: gas control as the manual says; no burner work.

Sources

  1. SAWS — Water quality troubleshooting, hard water row (checked Nov. 11, 2026)
  2. DOE Energy Saver Guide (2022) — quart-every-3-months advice (checked Nov. 11, 2026)
  3. SAWS — FAQs on typical hardness (checked Nov. 11, 2026)
  4. SAWS — Backflow testing page, relief valve note (checked Nov. 11, 2026)