Skip to the reports
Aquifer to TapSan Antonio house water, filed in short reports
Beats

Your waterW-04

SAWS uses free chlorine, not chloramine

Filed Nov. 11, 2026 · checked against 3 sources · Aquifer to Tap

SAWS disinfects with free chlorine, not chloramine, and its 2026 Water Quality Report puts the 2025 average free chlorine residual in the distribution system at 1.46 ppm, against a 4 ppm maximum.

1.46 ppmaverage free chlorine residual in SAWS pipes, 2025Source: SAWS 2026 Water Quality Report

The residual ranged from 0.16 to 3.7 ppm across the system in 2025, the 2026 report shows, and was marked "No" for violation. The maximum residual disinfectant level is 4 ppm. Neither the report nor SAWS's FAQ mentions chloramine anywhere.

Why is chlorine in the water at all?

SAWS's water quality FAQ says chlorine keeps water free of bacteria "as it travels through the many miles of water mains." SAWS adds about 1.0 part per million at its production facilities. TCEQ requires at least 0.2 ppm to remain in the water and allows no more than 4 ppm.

The report gives a range rather than one number because residual is measured at many points in the network. Neither SAWS source breaks the reading down by neighborhood.

Free chlorine and chloramine are different chemicals

EPA describes chloramines as most commonly formed when ammonia is added to chlorine. They last longer in pipes, and more than one in five Americans drinks water treated with them. EPA notes that some systems switched to chloramine as a secondary disinfectant to meet limits on disinfection byproducts. SAWS's 2026 report lists only free chlorine; its 2025 byproduct results are in TTHM and HAA5 in the 2026 report.

The difference matters mostly to people who treat water at home. Advice written for chloraminated cities, about which filters or conditioners remove chloramine, does not automatically apply in San Antonio. None of the official sources used here give dosing advice for aquariums or ponds; the maker of a water conditioner is the place to look for that.

SAWS chlorine figures (checked Nov. 11, 2026)
MeasureValueSource
Disinfectant typefree chlorine2026 Water Quality Report
Added at plantsabout 1.0 ppmSAWS FAQ
2025 average in pipes1.46 ppm2026 Water Quality Report
2025 range in pipes0.16-3.7 ppm2026 Water Quality Report
State minimum0.2 ppmTCEQ, as SAWS states
Maximum allowed4 ppmMRDL in report

Taste, smell and filters

The 2025 residual stayed under the 4 ppm limit at every reading, and the report adds that home treatment devices may offer no health gain for water that meets federal standards. A carbon filter is one option some households choose for taste; that is a preference, not a fix for unsafe water.

Chlorine is also not what leaves white crust on fixtures; that is calcium carbonate, the subject of the hardness numbers. For everything else in the yearly report, see the 2026 report summary.

Key facts

  • SAWS disinfectant: free chlorine, not chloramine
  • 2025 average residual 1.46 ppm; range 0.16-3.7 ppm; limit 4 ppm
  • About 1.0 ppm added at SAWS plants
  • TCEQ minimum residual: 0.2 ppm
  • EPA: chloramines form when ammonia is added to chlorine

Sources

  1. SAWS — 2026 Water Quality Report, residual disinfectant table (checked Nov. 11, 2026)
  2. SAWS — why chlorine is added, FAQ answer (checked Nov. 11, 2026)
  3. EPA — Chloramines in Drinking Water, disinfectant basics (checked Nov. 11, 2026)