Your waterW-02
What the 2026 SAWS Water Quality Report says
Filed Nov. 11, 2026 · checked against 3 sources · Aquifer to Tap
The 2026 SAWS Water Quality Report, built on 2025 data, says the SAWS main system received no violations in 2025, with every listed contaminant marked "No" in the violation column.
0violations for the SAWS main system in 2025Source: SAWS 2026 Water Quality Report

The report covers the main system, public water system ID TX0150018. Its tables give each substance, the sampling year, the highest level found, the range, the federal goal (MCLG), the legal limit (MCL or action level) and a yes-or-no violation column. Results for lead and copper come from customer taps sampled in 2024; most others come from 2025 samples at the plants or in the pipe network. SAWS posts the same tables as a printable PDF.
Which numbers matter most for a house?
Lead at the tap: the 90th percentile was 1.6 ppb against an action level of 15 ppb, with no sites over, according to the 2026 report. Copper's 90th percentile was 0.187 ppm against 1.3. The report lists corrosion of household plumbing as the likely source of both, which is why a home's own service line and fixtures matter; see lead service lines and Project Lead.
Bacteria: SAWS samples 390 sites in the distribution system each month and found no E. coli positives in 2025. Coliforms were found, which triggered required assessments.
| Substance | Highest or 90th pct. | Limit | Units | Violation |
|---|---|---|---|---|
| Lead (taps, 2024) | 1.6 | 15 (action level) | ppb | No |
| Copper (taps, 2024) | 0.187 | 1.3 (action level) | ppm | No |
| Nitrate as nitrogen | 2.45 | 10 | ppm | No |
| Barium | 0.125 | 2 | ppm | No |
| Combined radium 226/228 | 1.5 | 5 | pCi/L | No |
| Fluoride | 0.69 | 4 | ppm | No |
| Free chlorine residual (average) | 1.46 | 4 (MRDL) | ppm | No |
| TTHM (highest location average) | 86.2 | 80 | ppb | No |
| HAA5 (highest location average) | 30.6 | 60 | ppb | No |
The TTHM line stands out because 86.2 is above 80 and still marked "No". The report does not explain that pairing; the disinfection byproducts report sets out exactly what it does say. Under unregulated contaminants, the report lists lithium at an average of 15.6 ppb from federal UCMR 5 sampling.
What the report leaves out
Hardness, sodium, iron and other secondary constituents are absent. The report says they "may affect the appearance and taste" of water, are regulated by the State of Texas rather than EPA, and that the state's Drinking Water Watch posts them. SAWS does publish a hardness range elsewhere; it is covered here.
The report also notes that TCEQ has not completed a source water susceptibility assessment for the system, and it lists the aquifers and suppliers behind the water, summarized in the supply-source report. On bottled water and home filters, the report says that when water meets federal standards "there may not be any health benefits" to buying them.
SAWS's water quality page adds that TCEQ has rated the system superior since 1936, a SAWS statement.
Next to watch The next yearly report will carry 2026 data, including the TTHM locational averages.
Key facts
- Main system TX0150018: no violations in 2025
- Lead 90th percentile 1.6 ppb vs 15 ppb action level (2024 taps)
- 390 bacteria sites a month; no E. coli positives in 2025
- TTHM 86.2 ppb highest locational average, marked "No"
- Secondaries, including hardness, not reported; posted on Texas Drinking Water Watch
Sources
- SAWS — 2026 Main System Water Quality Report (2025 data) (checked Nov. 11, 2026)
- SAWS — 2026 Water Quality Report, printable PDF (checked Nov. 11, 2026)
- SAWS — Water Quality overview page (checked Nov. 11, 2026)